Three Opamp Differential Instrumentation

This is the best Instrumentation OpAmp, Great CMRR, ensure supply has no ripple and keep analog and digital grounds separate. Ri can be replaced with a trimpot and resistor to alter gain. Connect a preset ends to pins 1 and 8 and preset wiper to VCC for Offset Null when high gains are configured.

Thermocouple and Pt-100 RTD

The Input zeners and diodes form a protective clamp for all voltages above VCC-VDD. If supply is changed to +12 -12 change zeners to 12V zeners. Use similar Zeners at output to protect Output from being zapped by overvoltages or high energy – voltage*frequency transients. Add plastic capacitors across Rf for damping AC operation or ripple. Also avoid floating inputs by providing a bias.

3 Op-Amp Differential Instrumentation Amp

Vout = (Vp – Vn) * (2Rf+Ri)/Ri

Related Reading

  • Edison Bulb Life Extender
    The Edsion Filament lamp may be less popular, but it is the most cost-effective light even today. It is very affordable, The light is soothing [...]
  • Isolated dual power supply from 5V
    This is a unregulated supply for low power circuits. You may be able to regulate the outputs with zeners or small regulators like 78L05. The [...]
  • Ammeter and Precision Rectifier
    Studying current measurement is a prerequisite for many of the measuring techniques. The current parameter mainly specifies the power consumption in a circuit, given the [...]
  • Timer and Counter ModulesTimer and Counter Modules
    U1 CD4541 is a Timer with Long Duration Ability. This timer is started by a low pulse from earlier circuit, when the temperature goes above [...]
  • Precision Amplifier with Digital uC Control
    When Instruments are designed a analog front end is essential and also as most equipment have digital or microcontroller interface the analog circuit needs to [...]
  • Interface ICL7135 Voltmeter to PC
    A PC based Analog Voltmeter. The Printer Port or Parallel Port Interface is used to acquire high resolution analog data using ICL7135. This is a [...]
  • FET Current Source and MOSFET
    This is a constant current source using a FET. This is the most simple replacement to series resistor to limit current. The N-Channel FET BF256C [...]
  • Using Thermocouple with DMM or DVMUsing Thermocouple with DMM or DVM
    In the circuit, use only metal film resistors (MFR) of 1 per cent tolerance, as this is an instrumentation application. Power supply should be a [...]
About delabs 160 Articles